, Hicham Asmi, Farida Bentayeb, Faustino Bonutti
Published: 1 January 2020
Indian Journal of Nuclear Medicine, Volume 35, pp 210-215; https://doi.org/10.4103/ijnm.ijnm_11_20

Abstract:
Purpose: In single-photon emission computed tomography imaging, the presence of scatter degrades image quality. The goal of this study is to optimize the main- and sub-energy windows for triple-energy window (TEW) method using Monte Carlo SImulating Medical Imaging Nuclear Detectors (SIMIND) code for samarium-153 (Sm-153) imaging. Materials and Methods: The comparison is based on the Monte Carlo simulation data with the results estimated using TEW method. Siemens Symbia gamma-camera equipped with low-energy high-resolution collimator was simulated for Sm-153 point source located in seven positions in water cylindrical phantom. Three different main-energy window widths (10%, 15%, and 20%) and three different sub-energy window widths (2, 4, and 6 keV) were evaluated. We compared the true scatter fraction determined by SIMIND and scatter fraction estimated using TEW scatter correction method at each position. In order to evaluate the image quality, we used the full width at half maximum (FWHM) computed on the PSF and image contrast using Jaszczak phantom. Results: The scatter fraction using TEW method is similar to the true scatter fraction for 20% of the main-energy window and 6 keV sub-energy windows. For these windows, the results show that the resolution and contrast were improved. Conclusion: TEW method could be a useful scatter correction method to remove the scatter event in the image for Sm-153 imaging.
Published: 1 January 2020
Journal of Medical Physics, Volume 45, pp 107-115; https://doi.org/10.4103/jmp.jmp_5_20

Abstract:
Introduction: Detection of compton scattered photons is one of the most important factors affecting the quality of single-photon emission computed tomography (SPECT) images. In most cases, the multiple-energy window acquisition methods are used for estimation of the scatter contribution into the main energy window(s) used in imaging. Aims and Objectives: The purpose of this study is to evaluate and compare the performance of four different scatter correction methods in In-111 SPECT imaging. Due to the lack of sufficient studies in this field, it can be useful to perform a more detailed and comparative study. Materials and Methods: Four approximations for scatter correction of In-111 SPECT images are evaluated by using the Monte Carlo simulation. These methods are firstly applied on each of photopeak windows, separately. Then, the effect of the correction methods is investigated by considering both the photopeak windows. The images obtained from a simulated multiple-spheres phantom are used for the evaluation of the correction methods by using three assessment criteria, including the image contrast, relative noise, and the recovery coefficient. Results: The results of this study show that the correction methods, when using the single photopeak windows, result in increase in image contrast with a significant level of noise. In return, when both the photopeak energy windows are used for imaging, it is possible to achieve the better image characteristics. Conclusion: The use of the proposed correction methods, by considering both the photopeak windows, leads to improve the image contrast with a reasonable level of image noise.
Published: 1 January 2020
Journal of Medical Physics, Volume 45, pp 44-51; https://doi.org/10.4103/jmp.JMP_88_19

Abstract:
Background: Monte Carlo (MC) simulation codes are used extensively for modeling the nuclear medicine imaging systems, such as single photon emission computed tomography (SPECT) and positron emission tomography (PET). By using these codes, it is possible to set different imaging parameters and do various studies in the field of nuclear medicine imaging. Aims and Objectives: The aim of this study is to investigate the effective factors in improvement of the SPECT image quality by using MC simulation. Materials and Methods: In this study, we used the SIMIND MC simulation code and Jaszczak phantom containing six spheres with different diameters placed into a water-filled cylindrical phantom for consideration of the effects of different factors on quality of the images obtained from Tc-99m SPECT imaging system. The assessment criteria used to investigate these factors included image contrast, signal-to-noise ratio (SNR) and relative noise of the background (RNB). Results: The results of this study show that the right choice of the arc of rotation, the image matrix size, the number of angular views, type of the collimators, and also filters used in the image reconstruction affect the quality of SPECT images. Also, we show that use of scatter correction methods can improve the image quality. Conclusion: The MC simulation is a suitable tool for investigation of different factors affecting the quality of SPECT images, essentially in the studies based on the energy spectrum, such as the evaluation of the scatter correction methods.