Mechanical in vitro fatigue testing of implant materials and components using advanced characterization techniques
Open Access
- 30 November 2021
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (4), 898-909
- https://doi.org/10.1002/jbm.b.34970
Abstract
Implants of different material classes have been used for the reconstruction of damaged hard and soft tissue for decades. The aim is to increase and subsequently maintain the patient's quality of life through implantation. In service, most implants are subjected to cyclic loading, which must be taken particularly into consideration, since the fatigue strength is far below the yield and tensile strength. Inaccurate estimation of the structural strength of implants due to the consideration of yield or tensile strength leads to a miscalculation of the implant's fatigue strength and lifetime, and therefore, to its unexpected early fatigue failure. Thus, fatigue failure of an implant based on overestimated performance capability represents acute danger to human health. The determination of fatigue strength by corresponding tests investigating various stress amplitudes is time-consuming and cost-intensive. This study summarizes four investigation series on the fatigue behavior of different implant materials and components, following a standard and an in vitro short-time testing procedure, which evaluates the material reaction in one enhanced test set-up. The test set-up and the applied characterization methods were adapted to the respective application of the implant with the aim to simulate the surrounding of the human body with laboratory in vitro tests only. It could be shown that by using the short-time testing method the number of tests required to determine the fatigue strength can be drastically reduced. In future, therefore it will be possible to exclude unsuitable implant materials or components before further clinical investigations by using a time-efficient and application-oriented testing method.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (394479422)
This publication has 71 references indexed in Scilit:
- The effect of fatigue loading on the screw joint stability of zirconium abutmentJournal of Prosthodontic Research, 2013
- Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysisDental Materials, 2012
- Characterization of Ti–6Al–4V open cellular foams fabricated by additive manufacturing using electron beam meltingMaterials Science and Engineering: A, 2010
- Bioabsorbable Coronary StentsCirculation: Cardiovascular Interventions, 2009
- Characterization and Accelerated Ageing of UHMWPE Used in Orthopedic Prosthesis by PeroxideMaterials, 2009
- UHMWPE for arthroplasty: past or future?Journal of Orthopaedics and Traumatology, 2008
- Comparative cyclic stress-strain and fatigue resistance behavior of electron-beam- and gamma-irradiated ultrahigh molecular weight polyethyleneJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2004
- Fatigue of bone and bones: An analysis based on stressed volumeJournal of Orthopaedic Research, 1998
- Computer‐supported infrared spectrometry of polyethylene, ethene copolymers, and amorphous poly(alkyl ethylene)sMakromolekulare Chemie. Macromolecular Symposia, 1986