Non-Invasive Heart State Monitoring an Article on Latest PPG Processing
Open Access
- 22 November 2018
- journal article
- Published by Oriental Scientific Publishing Company in Biomedical and Pharmacology Journal
- Vol. 11 (4), 1885-1893
- https://doi.org/10.13005/bpj/1561
Abstract
Health Monitoring has become one of the most important task of this century with a change in population demography to build a smart healthcare system to give proper treatment to the correct patient with reduced cost, more consistently for better living. Heart & it's related parameters are very important for good health condition. Statistics from Centers for Disease Control and Prevention, in 2008, around 616K people died of heart disease and 25% cause of total death and in 2010 the percentage grew up to 31%. High blood pressure, high cholesterol, diabetes, smoking, overweight are some of the real cause of heart disease. To determine heart state, ECG is a proven and well accepted system. But, the device is expensive and requires training. ECG sensor measures the bio-potential generated by the electrical signals that is responsible to control the expansion and contraction of heart chambers. In this article, we have focused literature review on Non-Invasive cardiovascular monitoring researches undertaken so far to provide new possibilities and research trends so that we can monitor our health better and take precautions earlier with the use and advancement of Computer Science & Technology. Here we have primarily focused on PPG signal and its application to measure important blood parameters like Glucose, HB, SP02 that indirectly or directly can provide us a status of our health when required. Recent report suggests that PPG is very useful for measuring heart rates, arterial age (with PPG derivatives), blood pressure, oxygen saturation, emotion detection, respiratory rate etc. Accurate measurement of PPG can open up new possibilities in non-invasive computer aided cardiac research for smart care-giving.Keywords
This publication has 12 references indexed in Scilit:
- PPG Based Heart Rate Algorithm Improvement with Butterworth IIR Filter and Savitzky-Golay FIR FilterPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2018
- Non-Invasive CardioVascular MonitoringJournal of Environmental Science, Computer Science And Engineering & Technology, 2017
- Raman Spectroscopy as a Promising Tool for Noninvasive Point-of-Care Glucose MonitoringJournal of Diabetes Science and Technology, 2014
- Real-Time Heart Rate Monitoring System based on Ring-Type Pulse Oximeter SensorJournal of Electrical Engineering & Technology, 2013
- Development of a wristwatch-type PPG array sensor modulePublished by Institute of Electrical and Electronics Engineers (IEEE) ,2011
- Noise reduction of PPG signals using a particle filter for robust emotion recognitionPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2011
- Automated beat onset and peak detection algorithm for field-collected photoplethysmograms2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2009
- Evaluating the Relationship Between Arterial Blood Pressure Changes and Indices of Pulse Oximetric PlethysmographyAnesthesia & Analgesia, 2002
- Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusionCritical Care Medicine, 2002
- Pulse oximetry plethysmographic waveform during changes in blood volumeBritish Journal of Anaesthesia, 1999