A review of flash glucose monitoring in type 2 diabetes
Open Access
- 9 April 2021
- journal article
- review article
- Published by Springer Science and Business Media LLC in Diabetology & Metabolic Syndrome
- Vol. 13 (1), 1-10
- https://doi.org/10.1186/s13098-021-00654-3
Abstract
Continuous glucose monitoring systems are increasingly being adopted as an alternative to self-monitoring of blood glucose (SMBG) by persons with diabetes mellitus receiving insulin therapy. The FreeStyle Libre flash glucose monitoring system (Abbott Diabetes Care, Witney, United Kingdom) consists of a factory-calibrated sensor worn on the back of the arm which measures glucose levels in the interstitial fluid every minute and stores the reading automatically every 15 min. Swiping the reader device over the sensor retrieves stored data and displays current interstitial glucose levels, a glucose trend arrow, and a graph of glucose readings over the preceding 8 h. In patients with type 2 diabetes (T2D) receiving insulin therapy, pivotal efficacy data were provided by the 6-month REPLACE randomized controlled trial (RCT) and 6-month extension study. Compared to SMBG, the flash system significantly reduced the time spent in hypoglycemia and frequency of hypoglycemic events, although no significant change was observed in glycosylated hemoglobin (HbA1c) levels. Subsequent RCTs and real-world chart review studies have since shown that flash glucose monitoring significantly reduces HbA1c from baseline. Real-world studies in both type 1 diabetes or T2D populations also showed that flash glucose monitoring improved glycemic control. Higher (versus lower) scanning frequency was associated with significantly greater reductions in HbA1c and significant improvements in other measures such as time spent in hypoglycemia, time spent in hyperglycemia, and time in range. Additional benefits associated with flash glucose monitoring versus SMBG include reductions in acute diabetes events, all-cause hospitalizations and hospitalized ketoacidosis episodes; improved well-being and decreased disease burden; and greater treatment satisfaction. T2D patients who use flash glucose monitoring might expect to achieve significant improvement in HbA1c and glycemic parameters and several associated benefits.Keywords
Funding Information
- Abbott
This publication has 26 references indexed in Scilit:
- Flash glucose monitoring improves glycemia in higher risk patients: a longitudinal, observational study under real-life settingsBMJ Open Diabetes Research & Care, 2019
- Continuous Glucose Monitoring: A Brief Review for Primary Care PractitionersAdvances in Therapy, 2019
- Freestyle Libre Glucose Monitoring SystemClinical Diabetes, 2018
- Real-world flash glucose monitoring patterns and associations between self-monitoring frequency and glycaemic measures: A European analysis of over 60 million glucose testsDiabetes Research and Clinical Practice, 2018
- Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 DiabetesDiabetes Technology & Therapeutics, 2017
- Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 DiabetesDiabetes Therapy, 2017
- Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: a Multicenter, Open-Label Randomized Controlled TrialDiabetes Therapy, 2016
- Improvement in Glucose Control in Difficult-to-Control Patients With Diabetes Using a Novel Flash Glucose Monitoring DeviceJournal of Diabetes Science and Technology, 2016
- A Structured Self-Monitoring of Blood Glucose Approach in Type 2 Diabetes Encourages More Frequent, Intensive, and Effective Physician Interventions: Results from the STeP StudyDiabetes Technology & Therapeutics, 2011