Uniaxial Compressive Behavior of Concrete Columns Confined with Superelastic Shape Memory Alloy Wires

Abstract
Superelastic shape memory alloy (SMA) exhibits the ability to undergo large deformations before reverting back to its undeformed shape following the removal of the load. This unique property underlies its great potential in the seismic design and retrofitting of structure members. In this paper, superelastic SMA wires were utilized to confine concrete cylinders to enhance their axial compressive behavior. The axial carrying and deformation capacities of SMA-confined concrete cylinders are assessed by uniaxial compression testing on a total of eight SMA-confined concrete columns and one unconfined column. The influence of the amount of SMA and the prestrain level of SMA wires, as well as the reinforcing mode, on the axial carrying and deformation capacity of confined concrete columns were considered. The analysis focuses on the axial carrying capacity and deformation performance of concrete columns reinforced with superelastic SMA under different loading conditions. Based on the experimental data and analysis results, it is found that superelastic SMA wires can increase the axial loading capacity and enhance deformation performance of concrete columns. Under the same loading condition, the ultimate bearing capacity of SMA-confined concrete columns increases as the increasing of the amount of SMA wire. The results of this study verify the effectiveness of superelastic SMA in enhancing the loading capacity and deformation behavior of concrete cylinders.