Numerical Analysis of the Equivalent Stress at the Interface Bone/Threaded Dental Implant
- 10 October 2017
- journal article
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 34, 82-93
- https://doi.org/10.4028/www.scientific.net/jbbbe.34.82
Abstract
The purpose of this study was to develop a new three-dimensional model of an osseointegrated molar dental prosthesis and to carry out finite element analysis to evaluate stress distributions and intensities in the bone and in the components of dental prosthesis under three loads (corono-apical, distal-mesial and buccal-lingual) were applied to the top of the occlusal face of the prosthesis crown. The interfacial stresses were also determined inside and outside of the threading when the dental prosthesis system was subjected to one of three masticatory loads. All materials used in the models were considered to be isotropic, homogeneous and linearly elastic. The elastic properties, loads and constraints used in the model were taken from published data. In this study, the stress concentration occurred around the threaded dental implant neck. Thus, this area should be preserved clinically in order to maintain the bone–implant interface structurally and functionally.Keywords
This publication has 10 references indexed in Scilit:
- Stress distribution in dental prosthesis under an occlusal combined dynamic loadingMaterials & Design (1980-2015), 2012
- Analysis of the effect of load direction on the stress distribution in dental implantMaterials & Design (1980-2015), 2009
- Static, dynamic and fatigue behaviors of dental implant using finite element methodAdvances in Engineering Software, 2006
- Finite element analysis of three designs of an implant-supported molar crownThe Journal of Prosthetic Dentistry, 2004
- Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three‐dimensional finite element analysisClinical Oral Implants Research, 2004
- Critical review of immediate implant loadingClinical Oral Implants Research, 2003
- Anisotropic elastic properties of cancellous bone from a human edentulous mandibleClinical Oral Implants Research, 2000
- Elastic modulus of the periodontal ligamentBiomaterials, 1997
- The Elastic Properties of a Human MandibleAdvances in Dental Research, 1987
- Current evaluation of plastics in crown and bridge prosthesisThe Journal of Prosthetic Dentistry, 1963