Currently available motion-preserving orthopedic implants offer many advantages but have several limitations to their use, including short device lifetime, high part count, loss of natural kinematics and wear-induced osteolysis and implant loosening. Compliant mechanisms have been used to address some of these problems as they offer several potential advantages - namely wear reduction, reduced part count, and the ability to achieve complex, patient-specific motion profiles. This article provides a systematic review of compliant mechanisms as orthopedic implants. Based on the PRISMA guidelines for an efficient review, this work identified fourteen implantable orthopedic devices that seek to restore anatomical motion by utilizing mechanical compliance. From reviewing these implants and their results, advantages and consequences for each are summarized. Trends were also identified in how these devices are capable of mitigating common challenges found in orthopedic design. Design considerations for the development of future compliant orthopedic implants are proposed and discussed.Keywords
This publication has 72 references indexed in Scilit:
- Spinal Implant Development, Modeling, and Testing to Achieve Customizable and Nonlinear StiffnessJournal of Medical Devices, 2012
- Biomechanical Validation of Finite Element Models for Two Silicone Metacarpophalangeal Joint ImplantsJournal of Biomechanical Engineering, 2011
- Anatomically Neutral Silicone Small Joint Arthroplasty for OsteoarthritisThe Journal of Hand Surgery, 2009
- Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapiesArthritis Research & Therapy, 2007
- Metacarpophalangeal joint mechanics after 3 different silicone arthroplastiesThe Journal of Hand Surgery, 2004
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- The Titanium Grommet in Flexible Implant Arthroplasty of the Radiocarpal JointPlastic and Reconstructive Surgery, 1995
- Silicone SynovitisJournal of Hand Surgery (European Volume), 1994
- Swanson silicone arthroplasty of the wrist in rheumatoid arthritis: A long-term follow-upThe Journal of Hand Surgery, 1992
- Flexible device for vertebral body replacementJournal of Biomedical Engineering, 1989