Objectives: The aim of the current study was to compare intraocular pressure (IOP), hemodynamic parameters and throat pain in the use of C-MAC videolaryngoscope and the Macintosh laryngoscope under general anesthesia requiring endotracheal intubation. Methods: Seventy- eight patients aged 18-65 years, ASA ( American Society of Anesthesiologists physical status). I-II, who underwent elective surgery under general anesthesia were scheduled in the study. The groups were allocated as Group M (Macintosh laryngoscope) and Group VL (videolaryngoscope). Standard anesthesia technique was used in both groups. To assess the depth of anesthesia which was kept between 40 and 60, a Bispectral Index Monitor Model 2000 (Aspect Medical Systems, Inc, Newton, MA) was used throughout the study. We recorded hemodynamic variables, oxygen saturation before induction, at the 3rd and at the 10th minutes after intubation. The duration of intubation was recorded as the time from the laryngoscope entering the mouth to removal with end-tidal carbon dioxide on the monitor. IOP was measured before induction, and at the 3rd and 10th minutes after intubation. Inhalation agent was given after intubation. 78 patients were included in the study. We recorded cough after extubation, and postoperative sore throat was evaluated by an anesthesiologist who was blinded to the group allocations at 10 minutes and at 24 hours postoperatively. Results: There was no significant difference between the groups regarding age (p > 0.05), mean b ody mass index (p = 0.157), mean ASA (p = 0.475), mean b ispectral index values (p = 0.084) and mean operating time (p = 0.068). The mean duration of intubation was determined to be statistically significantly longer in Group M than in Group VL (p = 0.0001). There was no statistically significant difference between the groups regarding Modified Mallampati Score (p = 0.571) and Cormack Lehane Score (p = 0.819). The mean IOP at 3rd minute after intubation was determined to be statistically significantly higher in Group M (p = 0.0001). There was no statistically significant difference between the groups in regarding cough after extubation (p = 0.549), throat pain at 10 minutes (p = 0.662) and at 24 hours postoperatively. Conclusions: C-MAC videolaryngoscope can be recommended as the first choice in patients with high IOP requiring general anesthesia with endotracheal intubation.Keywords
This publication has 10 references indexed in Scilit:
- C-MAC compared with direct laryngoscopy for intubation in patients with cervical spine immobilization: A manikin trialThe American Journal of Emergency Medicine, 2017
- Intraocular pressure changes: the McGrath video laryngoscope vs the Macintosh laryngoscope; a randomized trialJournal of Clinical Anesthesia, 2016
- C-MAC® video laryngoscope with D-BLADE™ and Frova introducer for awake intubation in a patient with parapharyngeal massSaudi Journal of Anaesthesia, 2016
- A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgeryBrazilian Journal of Anesthesiology (English Edition), 2016
- Does the incidence of sore throat postoperatively increase with the use of a traditional intubation blade or the GlideScope?Journal of Clinical Anesthesia, 2015
- Hemodynamic Changes Following Endotracheal Intubation in Patients Undergoing Cesarean Section With General Anesthesia: Application of Glidescope® Videolaryngoscope Versus Direct LaryngoscopeAnesthesiology and Pain Medicine, 2015
- Influence of GlideScope assisted endotracheal intubation on intraocular pressure in ophthalmic patientsSaudi Journal of Anaesthesia, 2015
- Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysisCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2011
- Ketamine gargle for attenuating postoperative sore throatBritish Journal of Anaesthesia, 2008
- Haemodynamic changes and heart rate variability during midazolam-propofol co-inductionAnaesthesia, 2007