Novel web application for self-assessment of distance visual acuity to support remote consultation: a real-world validation study in children
Open Access
- 30 September 2021
- journal article
- research article
- Published by BMJ in BMJ Open Ophthalmology
- Vol. 6 (1), e000801
- https://doi.org/10.1136/bmjophth-2021-000801
Abstract
Objective The difficulty in accurately assessing distance visual acuity (VA) at home limits the usefulness of remote consultation in ophthalmology. A novel web application, DigiVis, enables automated VA self-assessment using standard digital devices. This study aims to compare its accuracy and reliability in children with clinical assessment by a healthcare professional. Methods and Analysis Children aged 4–10 years were recruited from a paediatric ophthalmology service. Those with VA worse than +0.8 logMAR (Logarithm of the Minimum Angle of Resolution) or with cognitive impairment were excluded. Bland-Altman statistics were used to analyse both the accuracy and repeatability of VA self-testing. User feedback was collected by questionnaire. Results The left eyes of 89 children (median 7 years) were tested. VA self-testing showed a mean bias of 0.023 logMAR, with a limit of agreement (LOA) of ±0.195 logMAR and an intraclass correlation coefficient (ICC) of 0.816. A second test was possible in 80 (90%) children. Test–retest comparison showed a mean bias of 0.010, with an LOA of ±0.179 logMAR, an ICC of 0.815 and a repeatability coefficient of 0.012. 96% of children rated the test as good or excellent, as did 99% of their parents. Conclusion Digital self-testing gave comparable distance VA assessments with clinical testing in children and was well accepted. Since DigiVis self-testing can be performed under direct supervision using medical video consultation software, it may be a useful tool to enable a proportion of paediatric eye clinic attendances to be moved online, reducing time off school and releasing face-to-face clinical capacity for those who need it.This publication has 12 references indexed in Scilit:
- Visual Acuity Testing for Telehealth Using Mobile ApplicationsJAMA Ophthalmology, 2021
- Parental Home Vision Testing of Children During Covid-19 PandemicBritish and Irish Orthoptic Journal, 2021
- Do the near computerised and non-computerised crowded Kay picture tests produce the same measure of visual acuity?British and Irish Orthoptic Journal, 2016
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Development and Validation of a Smartphone-Based Visual Acuity Test (Peek Acuity) for Clinical Practice and Community-Based FieldworkJAMA Ophthalmology, 2015
- Efficacy of a remote based computerised visual acuity measurementBritish Journal of Ophthalmology, 2012
- Validation of printed and computerised crowded Kay picture logMAR tests against gold standard ETDRS acuity test chart measurements in adult and amblyopic paediatric subjectsEye, 2011
- Validation of a computerised logMAR visual acuity measurement system (COMPlog): comparison with ETDRS and the electronic ETDRS testing algorithm in adults and amblyopic childrenBritish Journal of Ophthalmology, 2007
- Repeatability of ETDRS visual acuity in children.Investigative Ophthalmology & Visual Science, 2003
- Properties of some variants of adaptive staircases with fixed step sizesSpatial Vision, 2002