Test-Retest, Inter-Rater and Intra-Rater Reliability for Spatiotemporal Gait Parameters Using SANE (an eaSy gAit aNalysis systEm) as Measuring Instrument
Open Access
- 20 August 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (17), 5781
- https://doi.org/10.3390/app10175781
Abstract
Studies have demonstrated the validity of Kinect-based systems to measure spatiotemporal parameters of gait. However, few studies have addressed test-retest, inter-rater and intra-rater reliability for spatiotemporal gait parameters. This study aims to assess test-retest, inter-rater and intra-rater reliability of SANE (eaSy gAit aNalysis system) as a measuring instrument for spatiotemporal gait parameters. SANE comprises a depth sensor and a software that automatically estimates spatiotemporal gait parameters using distances between ankles without the need to manually indicate where each gait cycle begins and ends. Gait analysis was conducted by 2 evaluators for 12 healthy subjects during 4 sessions. The reliability was evaluated using Intraclass Correlation Coefficients (ICC). In addition, the Standard Error of the Measurement (SEM), and Smallest Detectable Change (SDC) was calculated. SANE showed from an acceptable to an excellent test-retest, inter-rater and intra-rater reliability; test-retest reliability ranged from 0.62 to 0.81, inter-rater reliability ranged from 0.70 to 0.95 and intra-rater ranged from 0.74 to 0.92. The subject behavior had a greater effect on the reliability of SANE than the evaluator performance. The reliability values of SANE were comparable with other similar studies. SANE, as a feasible and markerless system, has large potential for assessing spatiotemporal gait parameters.This publication has 35 references indexed in Scilit:
- Validity of the Kinect for Gait Assessment: A Focused ReviewSensors, 2016
- Walking Speed: The Functional Vital SignJournal of Aging and Physical Activity, 2015
- Summary measures for clinical gait analysis: A literature reviewGait & Posture, 2014
- Real-Time Range Imaging in Health Care: A SurveyLecture Notes in Computer Science, 2013
- Validity of the Microsoft Kinect for assessment of postural controlGait & Posture, 2012
- Efficacy of clinical gait analysis: A systematic reviewGait & Posture, 2011
- Real-time human pose recognition in parts from single depth imagesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2011
- Automated Markerless Analysis of Human Gait Motion for Recognition and ClassificationETRI Journal, 2011
- A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity MonitoringSensors, 2010
- Gait Characteristics of Elderly People With a History of Falls: A Dynamic ApproachPTJ: Physical Therapy & Rehabilitation Journal, 2006