Reproducibility of 2D versus 3D radiomics for quantitative assessment of fetal lung development: a retrospective fetal MRI study
Open Access
- 8 February 2023
- journal article
- research article
- Published by Springer Science and Business Media LLC in Insights into Imaging
- Vol. 14 (1), 1-9
- https://doi.org/10.1186/s13244-023-01376-y
Abstract
To investigate the reproducibility of radiomics features extracted from two-dimensional regions of interest (2D ROIs) versus whole lung (3D) ROIs in repeated in-vivo fetal magnetic resonance imaging (MRI) acquisitions. Thirty fetal MRI scans including two axial T2-weighted acquisitions of the lungs were analysed. 2D (lung at the level of the carina) and 3D (whole lung) ROIs were manually segmented using ITK-Snap. Ninety-five radiomics features were extracted from 2 and 3D ROIs in initial and repeat acquisitions using Pyradiomics. Radiomics feature intra-class correlation coefficients (ICC) were calculated between 2 and 3D ROIs in the initial acquisition, and between 2 and 3D ROIs in repeated acquisitions, respectively. MRI data of 11 (36.7%) female and 19 (63.3%) male fetuses acquired at a median 25 + 0 gestational weeks plus days (GW) (interquartile range [IQR] 23 + 4 − 27 + 0 GW) were assessed. Median radiomics feature ICC between 2 and 3D ROIs in the initial MRI acquisition was 0.733 (IQR 0.313–0.814, range 0.018–0.970). ICCs between radiomics features extracted using 3D ROIs in initial and repeat acquisitions (median 0.908 [IQR 0.824–0.929, range 0.335–0.996]) were significantly higher compared to 2D ROIs (0.771 [0.699–0.835, 0.048–0.965]) (p < 0.001). Fetal MRI radiomics features extracted from 3D whole lung segmentation masks showed significantly higher reproducibility across repeat acquisitions compared to 2D ROIs. Therefore, fetal MRI whole lung radiomics features are robust diagnostic and potentially prognostic tools in the image-based in-vivo quantitative assessment of lung development.Keywords
This publication has 34 references indexed in Scilit:
- Fetal lung apparent diffusion coefficient measurement using diffusion-weighted MRI at 3 Tesla: Correlation with gestational ageJournal of Magnetic Resonance Imaging, 2016
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Radiomics: Images Are More than Pictures, They Are DataRadiology, 2016
- Determination of Fetal Lung Maturity Using Magnetic Resonance Imaging Signal Intensity MeasurementsUltrasound Quarterly, 2014
- Assessment of lung development in isolated congenital diaphragmatic hernia using signal intensity ratios on fetal MR imagingEuropean Radiology, 2009
- Fetal Body Volume at MR Imaging to Quantify Total Fetal Lung Volume: Normal RangesRadiology, 2008
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006
- MRI of normal and pathological fetal lung developmentEuropean Journal of Radiology, 2006
- Fetal Relative Lung Volume: Quantification by Using Prenatal MR Imaging Lung VolumetryRadiology, 2004
- MR assessment of fetal lung development using lung volumes and signal intensitiesEuropean Radiology, 2004