Objectives: Thyroid scintigraphy using 99mTc -pertechnetate is commonly used to study function and structure of thyroid gland. Pin-hole collimator is generally preferred in thyroid scintigraphy and uptake studies . The purpose of the present study was to determine actual radiopharmaceutical uptake value in an experimental 99mTc-pertechnetate thyroid scintigraphy and uptake model. Methods: Thyroid hyperactive and hypoactive nodule models were created using 4 mCi (148 MBq) 99mTc-pertechnetate. In the experimental model, 4 mm, 6 mm and 8 mm diameter pin-hole collimators, and 5 cm, 7 cm and 10 cm object-to-pinhole distances were investigated. Results: In thyroid hyperactive nodule model, despite the same activity value, uptake at 7 cm object-to-pinhole distance was higher compared to 10 cm distance (122% and 103%, respectively). In the patient with Graves’ disease, despite the same activity value, uptake at 5 cm object-to-pinhole distance was higher compared to 10 cm distance (8% and 4%, respectively). In thyroid hypoactive nodule model, 4 mm, 6 mm and 8 mm diameters pin-hole collimators were imaged at 5 cm, 10 cm and 15 cm object-to-pinhole distances . The resolution differences between the images were evaluated. Conclusion: It was determined that imaging using 10 cm object-to-pinhole distance and 4 mm diameter pin-hole collimator was best in terms of image resolution and optimum 99mTc-pertechnetate uptake level.Keywords
This publication has 20 references indexed in Scilit:
- Inter- and intraobserver variability of (semi-)quantitative parameters commonly used in feline thyroid scintigraphyResearch in Veterinary Science, 2016
- Virtual-Pinhole PETJournal of Nuclear Medicine, 2008
- Normal values of [99mTc]pertechnetate uptake and excretion fraction by major salivary glandsNuclear Medicine Communications, 2006
- Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.Sao Paulo Medical Journal, 2002
- Thyroid suppression test with L‐thyroxine and [99mTc] pertechnetateClinical Endocrinology, 2000
- Review of convergent beam tomography in single photon emission computed tomographyPhysics in Medicine & Biology, 1992
- Estimation of 24-Hour Thyroid Uptake of 1-131 Sodium Iodide Using a 5-Minute Uptake of Technetium-99m PertechnetateClinical Nuclear Medicine, 1990
- Qualitätsverbesserung in der Schilddrüsenszintigraphie durch Verwendung von Gammakamera und Pin-hole-KollimatorRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1981
- The Anger Camera and the Pertechnetate Ion in the Routine Evaluation of Thyroid Uptake and ImagingClinical Nuclear Medicine, 1979
- Simple, rapid thyroid function testing with 99mTc-pertechnetate thyroid uptake ratio and neck/thigh ratioAmerican Journal of Roentgenology, 1979