Contact photolithography-free integration of patterned and semi-transparent indium tin oxide stimulation electrodes into polydimethylsiloxane-based heart-on-a-chip devices for streamlining physiological recordings
- 6 January 2021
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (4), 674-687
- https://doi.org/10.1039/d0lc00948b
Abstract
Controlled electrical stimulation is essential for evaluating the physiology of cardiac tissues engineered in heart-on-a-chip devices. However, existing stimulation techniques, such as external platinum electrodes or opaque microelectrode arrays patterned on glass substrates, have limited throughput, reproducibility, or compatibility with other desirable features of heart-on-a-chip systems, such as the use of tunable culture substrates, imaging accessibility, or enclosure in a microfluidic device. In this study, indium tin oxide (ITO), a conductive, semi-transparent, and biocompatible material, was deposited onto glass and polydimethylsiloxane (PDMS)-coated coverslips as parallel or point stimulation electrodes using laser-cut tape masks. ITO caused substrate discoloration but did not prevent brightfield imaging. ITO-patterned substrates were microcontact printed with arrayed lines of fibronectin and seeded with neonatal rat ventricular myocytes, which assembled into aligned cardiac tissues. ITO deposited as parallel or point electrodes was connected to an external stimulator and used to successfully stimulate micropatterned cardiac tissues to generate calcium transients or propagating calcium waves, respectively. ITO electrodes were also integrated into the cantilever-based muscular thin film (MTF) assay to stimulate and quantify the contraction of micropatterned cardiac tissues. To demonstrate the potential for multiple ITO electrodes to be integrated into larger, multiplexed systems, two sets of ITO electrodes were deposited onto a single substrate and used to stimulate the contraction of distinct micropatterned cardiac tissues independently. Collectively, these approaches for integrating ITO electrodes into heart-on-a-chip devices are relatively facile, modular, and scalable and could have diverse applications in microphysiological systems of excitable tissues.Keywords
Funding Information
- American Heart Association (16SDG29950005, 19POST34380814)
- National Science Foundation (1610604)
- University of Southern California
- Rose Hills Foundation
- National Institutes of Health (1R01HL153286-01)
This publication has 86 references indexed in Scilit:
- Development of Polydimethylsiloxane Substrates with Tunable Elastic Modulus to Study Cell Mechanobiology in Muscle and NervePLOS ONE, 2012
- Ensembles of engineered cardiac tissues for physiological and pharmacological study: Heart on a chipLab on a Chip, 2011
- Patterned cardiomyocytes on microelectrode arrays as a functional, high information content drug screening platformBiomaterials, 2011
- Biphasic Electrical Field Stimulation Aids in Tissue Engineering of Multicell-Type Cardiac OrganoidsTissue Engineering, Part A, 2011
- Surface-patterned electrode bioreactor for electrical stimulationLab on a Chip, 2010
- Nanoscale cues regulate the structure and function of macroscopic cardiac tissue constructsProceedings of the National Academy of Sciences of the United States of America, 2009
- Electrical stimulation systems for cardiac tissue engineeringNature Protocols, 2009
- Embryonic cardiomyocytes beat best on a matrix with heart-like elasticity: scar-like rigidity inhibits beatingJournal of Cell Science, 2008
- Proinflammatory cytokines tumor necrosis factor-α and interferon-γ alter tight junction structure and function in the rat parotid gland Par-C10 cell lineAmerican Journal of Physiology-Cell Physiology, 2008
- Comparison study of ITO thin films deposited by sputtering at room temperature onto polymer and glass substratesThin Solid Films, 2005