Engineering Aspects and Parameter Evaluation of Ozone Generator
- 31 March 2021
- journal article
- Published by World Scientific and Engineering Academy and Society (WSEAS) in WSEAS TRANSACTIONS ON ELECTRONICS
- Vol. 12, 19-23
- https://doi.org/10.37394/232017.2021.12.3
Abstract
This paper introduces the Ozone generator parameters analysis and its engineering design aspects. Practically, Ozone is successfully used in water treatment applications; furthermore, it can be used to treat the secondary system cooling water in nuclear research reactors. The main element in this process is the Ozone generator; it has many parameters that need to be set at its design. These parameters can be divided into those related to the electrical equivalent circuit of corona dielectric barrier discharge (DBD), those associated with injected gas flow between the two electrodes, and those belonging to temperature of the electrodes. This paper is intended to those parameters that are related to the electrical equivalent circuit which has two standard models: linear and nonlinear. In this regard, the determination of the component values of nonlinear model can be achieved very hardly. To handle such determination, the nonlinear model can be approximately treated as a linear model in an approaching fashion. Based on this approximation, Lissajous plot and differential evolution (DE) methodologies are used for the computation of DBD ozone chamber parameters. Additionally, a new theoretical technique will be presentedKeywords
This publication has 9 references indexed in Scilit:
- A Review of Recent Advances of Dielectric Barrier Discharge Plasma in CatalysisNanomaterials, 2019
- Comparative Experimental Study between Surface and Volume DBD Ozone GeneratorOzone: Science & Engineering, 2015
- A Model Parameter Extraction Method for Dielectric Barrier Discharge Ozone Chamber using Differential EvolutionMeasurement Science Review, 2014
- Design and implementation of a low cost, high yield dielectric barrier discharge ozone generator based on the single switch resonant converterIET Power Electronics, 2013
- A Simple and Effective Method to Estimate the Model Parameters of Dielectric Barrier Discharge Ozone ChamberIEEE Transactions on Instrumentation and Measurement, 2012
- DBD Modeling as a Function of Waveforms SlopePublished by Institute of Electrical and Electronics Engineers (IEEE) ,2007
- Linear and non linear models for ozone generators considering electrodes lossesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2004
- High Frequency Testing and Modeling of Silent Discharge Ozone GeneratorsOzone: Science & Engineering, 2003