New Search

Advanced search
Export article
Open Access

Harmonizing Newborn Screening Laboratory Proficiency Test Results Using the CDC NSQAP Reference Materials

Sciprofile linkCharles Austin Pickens, Sciprofile linkMaya Sternberg, Sciprofile linkMary Seeterlin, Sciprofile linkVíctor R. De Jesús, Sciprofile linkMark Morrissey, Sciprofile linkAdrienne Manning, Sciprofile linkSonal Bhakta, Sciprofile linkPatrice K. Held, Sciprofile linkJoanne Mei, Sciprofile linkCarla Cuthbert, Sciprofile linkKonstantinos Petritis
Published: 17 September 2020
 by  MDPI
International Journal of Neonatal Screening , Volume 6; doi:10.3390/ijns6030075

Abstract: Newborn screening (NBS) laboratories cannot accurately compare mass spectrometry-derived results and cutoff values due to differences in testing methodologies. The objective of this study was to assess harmonization of laboratory proficiency test (PT) results using quality control (QC) data. Newborn Screening Quality Assurance Program (NSQAP) QC and PT data reported from 302 laboratories in 2019 were used to compare results among laboratories. QC materials were provided as dried blood spot cards which included a base pool and the base pool enriched with specific concentrations of metabolites in a linear range. QC data reported by laboratories were regressed on QC data reported by the Centers for Disease Control and Prevention (CDC), and laboratory’s regression parameters were used to harmonize their PT result. In general, harmonization tended to reduce overall variation in PT data across laboratories. The metabolites glutarylcarnitine (C5DC), tyrosine, and phenylalanine were displayed to highlight inter- and intra-method variability in NBS results. Several limitations were identified using retrospective data for harmonization, and future studies will address these limitations to further assess feasibility of using NSQAP QC data to harmonize PT data. Harmonizing NBS data using common QC materials appears promising to aid result comparison between laboratories.
Keywords: Newborn Screening / mass spectrometry / normalization / metabolite / Proficiency Testing

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

Share this article

Click here to see the statistics on "International Journal of Neonatal Screening" .
References (29)
    Back to Top Top