Dielectric Elastomer Actuators, Neuromuscular Interfaces, and Foreign Body Response in Artificial Neuromuscular Prostheses: A Review of the Literature for an In Vivo Application
Open Access
- 4 June 2021
- journal article
- review article
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (13), e2100041
- https://doi.org/10.1002/adhm.202100041
Abstract
The inability to replace human muscle in surgical practice is a significant challenge. An artificial muscle controlled by the nervous system is considered a potential solution for this. Here, this is defined as a neuromuscular prosthesis. Muscle loss and dysfunction related to musculoskeletal oncological impairments, neuromuscular diseases, trauma or spinal cord injuries can be treated through artificial muscle implantation. At present, the use of dielectric elastomer actuators working as capacitors appears a promising option. Acrylic or silicone elastomers with carbon nanotubes functioning as the electrode achieve mechanical performances similar to human muscle in vitro. However, mechanical, electrical, and biological issues have prevented clinical application to date. Here materials and mechatronic solutions are presented which can tackle current clinical problems associated with implanting an artificial muscle controlled by the nervous system. Progress depends on the improvement of the actuation properties of the elastomer, seamless or wireless integration between the nervous system and the artificial muscle, and on reducing the foreign body response. It is believed that by combining the mechanical, electrical, and biological solutions proposed here, an artificial neuromuscular prosthesis may be a reality in surgical practice in the near future.Funding Information
- Australian Research Council (CE140100012)
This publication has 106 references indexed in Scilit:
- A Biosynthetic Nerve Guide Conduit Based on Silk/SWNT/Fibronectin Nanocomposite for Peripheral Nerve RegenerationPLOS ONE, 2013
- Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfacesNature Materials, 2012
- Immune complement activation is attenuated by surface nanotopographyInternational Journal of Nanomedicine, 2011
- Device-based local delivery of siRNA against mammalian target of rapamycin (mTOR) in a murine subcutaneous implant model to inhibit fibrous encapsulationJournal of Controlled Release, 2010
- Proangiogenic scaffolds as functional templates for cardiac tissue engineeringProceedings of the National Academy of Sciences of the United States of America, 2010
- The Effect of Surface Nanometre-Scale Morphology on Protein AdsorptionPLOS ONE, 2010
- Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial ArmsJAMA, 2009
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- Biomimetic materials for tissue engineeringAdvanced Drug Delivery Reviews, 2008
- Histamine release and fibrinogen adsorption mediate acute inflammatory responses to biomaterial implants in humansJournal of Translational Medicine, 2007