Indoor Particulate Matter Assessment in a Northern Nigerian Abattoir and a Residential Building

Abstract
Indoor air pollution in buildings puts people at risk of developing respiratoryand cardiovascular diseases. Particulate matter (PM) exposure is known tocause these health issues. Preliminary efforts were made in this study to assessthe quantity and quality of PM1.0, PM2.5, and PM10 present in an abattoir and aresidential building in northern Nigeria. Canree A1 low-cost sensor was used tomonitor the locations, 8 hourly for two weeks. The results showed that the average values (μg/m3 ) of PM1.0, PM2.5, and PM10 in an abattoir were 62.74, 161.94, and 199.08, respectively, and in a residential building were 28.70, 83.31, and 103.71. The average Air Quality Index (AQI) of the abattoir office was VeryUnhealthy, while the living room of the residential building was unhealthy. ThePM2.5, and PM10 levels were higher than the international (WHO) and national(FMEnv) standard limits, indicating a potential danger to building occupants.It is expected that the indoor environment of the locations will be improved bythe use of good ventilators (adequate windows and doors) and the provision ofgood extractors