Abstract
Glucose monitoring is vital for glycemic control in patients with diabetes mellitus (DM). Continuous glucose monitoring (CGM) measures whole-day glucose levels. Hemoglobin A1c (HbA1c) is a vital outcome predictor in patients with DM. This study investigated the relationship between HbA1c and CGM, which remained unclear hitherto. Data of patients with DM (n = 91) who received CGM and HbA1c testing (1–3 months before and after CGM) were retrospectively analyzed. Diurnal and nocturnal glucose, highest CGM data (10%, 25%, and 50%), mean amplitude of glycemic excursions (MAGE), percent coefficient of variation (%CV), and continuous overlapping net glycemic action were compared with HbA1c values before and after CGM. The CGM results were significantly correlated with HbA1c values measured 1 (r = 0.69) and 2 (r = 0.39) months after CGM and 1 month (r = 0.35) before CGM. However, glucose levels recorded in CGM did not correlate with the HbA1c values 3 months after and 2–3 months before CGM. MAGE and %CV were strongly correlated with HbA1c values 1 and 2 months after CGM, respectively. Diurnal blood glucose levels were significantly correlated with HbA1c values 1–2 months before and 1 month after CGM. The nocturnal blood glucose levels were significantly correlated with HbA1c values 1–3 months before and 1–2 months after CGM. CGM can predict HbA1c values within 1 month after CGM in patients with DM.Keywords
This publication has 42 references indexed in Scilit:
- Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetesDiabetology & Metabolic Syndrome, 2013
- The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring SystemKorean Diabetes Journal, 2010
- Translating the A1C Assay Into Estimated Average Glucose ValuesDiabetes Care, 2008
- Standards of Medical Care in Diabetes—2007Diabetes Care, 2007
- Improved Glycemic Control in Poorly Controlled Patients with Type 1 Diabetes Using Real-Time Continuous Glucose MonitoringDiabetes Care, 2006
- Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditionsDiabetes & Metabolism, 2003
- The Glucose Area Under the Profiles Obtained With Continuous Glucose Monitoring System Relationships With HbAlc in Pediatric Type 1 Diabetic PatientsDiabetes Care, 2002
- A desktop guide to Type 2 diabetes mellitusDiabetic Medicine, 1999
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- The Clinical Information Value of the Glycosylated Hemoglobin AssayThe New England Journal of Medicine, 1984