Wearable Sensor Systems for Fall Risk Assessment: A Review
Open Access
- 14 July 2022
- journal article
- review article
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 4, 921506
- https://doi.org/10.3389/fdgth.2022.921506
Abstract
Fall risk assessment and fall detection are crucial for the prevention of adverse and long-term health outcomes. Wearable sensor systems have been used to assess fall risk and detect falls while providing additional meaningful information regarding gait characteristics. The most commonly used wearable systems for this purpose are inertial measurement units (IMUs) which acquire data from accelerometers and gyroscopes. IMUs can be placed at various locations on the body to acquire motion data that can be further analyzed. Insole-based systems are wearable systems that have also been developed for fall risk assessment and fall detection. Insole-based systems are placed beneath the sole of the foot and typically obtain plantar pressure distribution data. Parameters relevant to falls that have been investigated using inertial sensor-based and insole-based devices include but are not limited to centre of pressure trajectory, postural stability, plantar pressure distribution and gait characteristics such as cadence, step length, single/double support ratio and stance/swing phase duration. The acquired data from inertial and insole-based systems can undergo various analysis techniques to render meaningful information regarding an individual’s fall risk or fall status. By assessing the merits and limitations of existing systems, future wearable sensors can be improved to allow for more accurate and convenient fall risk assessment. This manuscript reviews inertial sensor-based and insole-based wearable devices that have been developed for applications related to falls. Key points including spatiotemporal parameters, biomechanical gait parameters, physical activities and data analysis methods pertaining to recently developed systems, current challenges and future perspectives are described in this review.Keywords
Funding Information
- Canada Excellence Research Chairs, Government of Canada
- Natural Sciences and Engineering Research Council of Canada
This publication has 88 references indexed in Scilit:
- The harmonic ratio of trunk acceleration predicts falling among older people: results of a 1-year prospective studyJournal of NeuroEngineering and Rehabilitation, 2013
- Foot Plantar Pressure Measurement System: A ReviewSensors, 2012
- Gait Analysis Using Wearable SensorsSensors, 2012
- The Nonlinear Relationship Between Gait Speed and Falls: The Maintenance of Balance, Independent Living, Intellect, and Zest in the Elderly of Boston StudyJournal of the American Geriatrics Society, 2011
- Feature extraction and selection for objective gait analysis and fall risk assessment by accelerometryBioMedical Engineering OnLine, 2011
- The effect of gait velocity on calcaneal balance at heel strike; Implications for orthotic prescription in injury preventionGait & Posture, 2010
- Ambulatory measurement of 3D knee joint angleJournal of Biomechanics, 2008
- Use of the Berg Balance Scale for Predicting Multiple Falls in Community-Dwelling Elderly People: A Prospective StudyPTJ: Physical Therapy & Rehabilitation Journal, 2008
- Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderlyIEEE Transactions on Biomedical Engineering, 2002
- Fear of Falling among the Community-Dwelling ElderlyJournal of Aging and Health, 1993