Abstract
The outbreak of food-borne pathogens has become a serious concern; therefore, the detection of pathogenic bacteria in food is required. Untreated, sensitive, and reliable sensors should be developed for the detection of Staphylococcus aureus (S. aureus). In this study, a sensitive antibody-based electrochemical immunosensor was developed using antibody (Ab)-hierarchical mesoporous silica (HMS) bio-conjugates for label-free detection of low concentrations of S. aureus. First, a bio-template method based on butterfly wings was used to prepare the HMS. Then, the carrier material was amino-functionalized to cross-link the antibody with glutaraldehyde. The Ab-HMS bio-conjugates were then immobilized on a glassy carbon electrode (GCE), and the presence of S. aureus was detected by analyzing the changes in the peak currents after the antigen–antibody complex formation. Differential pulse voltammetry (DPV) was performed with bacterial concentrations ranging from 10 to 2 × 103 colony forming units (CFU) mL−1. Selective tests were performed using Escherichia coli (E. coli), Listeria monocytogenes (L. monocytohenes), and Salmonella, and the selective assays showed specific detection of S. aureus using the sensor. In addition, the immunosensor showed a good linear relationship between the peak current increase and logarithmic S. aureus concentration (R2 = 0.9759) with a fast detection time (20 min) and detection limit of 11 CFU mL−1. When the electrochemical impedance spectroscopy (EIS) was performed under the same conditions, the results showed a good linear relationship between the impedance change value and the bacterial concentration (R2 = 0.9720), the limit of detection (LOD) was 12 CFU mL−1. The performance of the sensor was compared with that of the colony counting method in the spiked milk sample test. The results showed no significant difference in the test results. Hence, this electrochemical immunosensor can be used to quickly detect S. aureus in actual food samples with a high sensitivity, specificity and stability.Funding Information
- National Natural Science Foundation of China (31572566, 31872525)
This publication has 47 references indexed in Scilit:
- Ag@BSA Core/Shell Microspheres As an Electrochemical Interface for Sensitive Detection of Urinary Retinal-Binding ProteinAnalytical Chemistry, 2012
- Plasma-assisted atomic layer deposition of Al2O3 and parylene C bi-layer encapsulation for chronic implantable electronicsApplied Physics Letters, 2012
- Probing the molecular structure of antimicrobial peptide-mediated silica condensation using X-ray photoelectron spectroscopyJournal of Materials Chemistry, 2012
- Hierarchical Mesoporous Silica Nanotubes Derived from Natural Cellulose SubstanceACS Applied Materials & Interfaces, 2011
- Wall Teichoic Acid Function, Biosynthesis, and InhibitionChemBioChem, 2009
- Biomorphic mineralization: From biology to materialsProgress in Materials Science, 2009
- Precision Replication of Hierarchical Biological Structures by Metal Oxides Using a Sonochemical MethodLangmuir, 2008
- Immunosensor for the determination of Staphylococcus aureus using a tyrosinase–mercaptopropionic acid modified electrode as an amperometric transducerAnalytical and Bioanalytical Chemistry, 2008
- Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodesBiosensors and Bioelectronics, 2007
- Amperometmc immunoassaysBioelectrochemistry and Bioenergetics, 1987