“Black ring-shaped burn” in button battery ingestion is not a burn — Comparison with charring using spectral CT
- 1 December 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 94 (1128)
- https://doi.org/10.1259/bjr.20210271
Abstract
To compare “black ring-shaped burn” (BRSB) and charring using spectral computed tomography (CT). Spectral CT was performed using chicken pectoralis minor muscle, processed in three ways and unprocessed as a control: a) BRSB generated by bringing the negative pole surface of a 3 V button battery (BB) into contact with the muscle; b) BRSB caused by a 1.5 V BB; c) charring caused by broiling; and d) control. Attenuation values were compared between BRSB and charring. Muscles were formalin-fixed and stained with Perls’ Prussian blue. Attenuation values from polychromatic 120-kVp images were significantly higher for BRSBs than for charring. In the spectral Hounsfield unit curve, attenuation values for BRSBs were higher for lower energy. Histopathologically, BRSBs stained positively with Perls’ Prussian blue. This study using spectral CT revealed that BRSB contains metal and confirmed the presence of Fe3+ histopathologically. BRSB differs from charring due to burns. The exact composition of BRSB remains unclear, but this report is the first to show that BRSB differs from charring using spectral CT. Clarification of the composition of BRSB is expected to facilitate the development of more effective BRSB removal therapy.This publication has 57 references indexed in Scilit:
- Severe tracheobronchial harm due to lithium button battery aspiration: An in vitro study of the pathomechanism and injury patternInternational Journal of Pediatric Otorhinolaryngology, 2020
- Double button battery ingestion – The “macaroon” signJournal of Pediatric Surgery Case Reports, 2018
- pH‐neutralizing esophageal irrigations as a novel mitigation strategy for button battery injuryThe Laryngoscope, 2018
- Button battery ingestion in children—a potentially catastrophic event of which all radiologists must be awareThe British Journal of Radiology, 2018
- Multi-energy spectral CT: adding value in emergency body imagingEmergency Radiology, 2017
- Basic mechanism of button battery ingestion injuries and novel mitigation strategies after diagnosis and removalThe Laryngoscope, 2016
- Sudden death following accidental ingestion of a button battery by a 17-month-old child: a case studyInternational journal of legal medicine, 2016
- Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Improved Image Quality as Compared with That Obtained with Conventional 120-kVp CTRadiology, 2011
- Emerging Battery-Ingestion Hazard: Clinical ImplicationsPEDIATRICS, 2010
- Fire DeathsPublished by Taylor & Francis Ltd ,2001