Abstract
Painless, needle-free, and continuous glucose monitoring sensors are needed to enhance the life quality of diabetic patients. To that extent, we propose a first-of-its-kind, highly sensitive, noninvasive continuous glycemic monitoring wearable multisensor system. The proposed sensors are validated on serum, animal tissues, and animal models of diabetes and in a clinical setting. The noninvasive measurement results during human trials reported high correlation (>0.9) between the system’s physical parameters and blood glucose levels, without any time lag. The accurate real-time responses of the sensors are attributed to their unique vasculature anatomy–inspired tunable electromagnetic topologies. These wearable apparels wirelessly sense hypo- to hyperglycemic variations with high fidelity. These components are designed to simultaneously target multiple body locations, which opens the door for the development of a closed-loop artificial pancreas.Keywords
Funding Information
- UKLTH
This publication has 33 references indexed in Scilit:
- Partial Least Squares RevisitedLong Range Planning, 2014
- Cole–cole model for glucose‐dependent dielectric properties of blood plasma for continuous glucose monitoringMicrowave and Optical Technology Letters, 2013
- Non-invasive glucose monitoring technology in diabetes management: A reviewAnalytica Chimica Acta, 2012
- Recent advances in noninvasive glucose monitoringMedical Devices: Evidence and Research, 2012
- Non-invasive glucose monitoring in patients with Type 1 diabetes: A Multisensor system combining sensors for dielectric and optical characterisation of skinBiosensors and Bioelectronics, 2009
- Continuous Glucose Monitoring: The Future of Diabetes ManagementDiabetes Spectrum, 2008
- Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy”Journal of Diabetes Science and Technology, 2007
- The Original Clarke Error Grid Analysis (EGA)Diabetes Technology & Therapeutics, 2005
- Noninvasive Glucose Monitoring by Reverse Iontophoresis in Vivo: Application of the Internal Standard ConceptClinical Chemistry, 2004
- Fetal Bovine Serum: A Multivariate StandardExperimental Biology and Medicine, 1975