A detective quantum efficiency for spectroscopic X‐ray imaging detectors
- 30 August 2021
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 48 (11), 6781-6799
- https://doi.org/10.1002/mp.15194
Abstract
Purpose: Spectroscopic x-ray detectors (SXDs) are under development for x-ray imaging applications. Recent efforts to extend the detective quantum efficiency (DQE) to SXDs impose a barrier to experimentation and/or do not provide a task-independent measure of detector performance. The purpose of this article is to define a task-independent DQE for SXDs that can be measured using a modest extension of established DQE-metrology methods. Methods: We defined a task-independent spectroscopic DQE and performed a simulation study to determine the relationship between the zero-frequency DQE and the ideal-observer signal-to-noise ratio (SNR) of low-frequency soft-tissue, bone, iodine and gadolinium signals. In our simulations, we used calibrated models of the spatio-energetic response of cadmium telluride (CdTe) and cadmium-zinc-telluride (CdZnTe) SXDs. We also measured the zero-frequency DQE of a CdTe detector with two energy bins and of a CdZnTe detector with up to six energy bins for an RQA9 spectrum and compared with model predictions. Results: The spectroscopic DQE accounts for spectral distortions, energy-bin-dependent spatial resolution, inter-bin spatial noise correlations, and intra-bin spatial noise correlations; it is mathematically equivalent to the squared signal-to-noise ratio per unit fluence of the generalized least squares estimate of the height of an x-ray impulse in a uniform noisy background. The zero-frequency DQE has a strong linear relationship with the ideal-observer SNR of low-frequency soft-tissue, bone, iodine and gadolinium signals, and can be expressed in terms of the product of the quantum efficiency and a Swank noise factor that accounts for DQE degradation due to (for example) charge sharing and electronic noise. The spectroscopic Swank noise factor of the CdTe detector was measured to be 0.81±0.04 and 0.83±0.04 with and without anti-coincidence logic for charge-sharing suppression, respectively. The spectroscopic Swank noise factor of the CdZnTe detector operated with four energy bins was measured to be 0.82±0.02 which is within 5% of the theoretical value. Conclusions: The spectroscopic DQE defined here is (1) task-independent, (2) can be measured using a modest extension of existing DQE-metrology methods, and (3) is predictive of the ideal-observer SNR of soft-tissue, bone, iodine and gadolinium signals. For CT applications, the combination of charge sharing and electronic noise in CdZnTe spectroscopic detectors will degrade the zero-frequency DQE by 10 % to 20 % depending on the electronic noise level and pixel size.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 43 references indexed in Scilit:
- Imaging properties of small-pixel spectroscopic x-ray detectors based on cadmium telluride sensorsPhysics in Medicine & Biology, 2012
- Multienergy Photon-counting K-edge Imaging: Potential for Improved Luminal Depiction in Vascular ImagingRadiology, 2008
- Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomographyPhysics in Medicine & Biology, 2008
- K-edge imaging in x-ray computed tomography using multi-bin photon counting detectorsPhysics in Medicine & Biology, 2007
- A framework for noise‐power spectrum analysis of multidimensional imagesMedical Physics, 2002
- Evaluation of a photon-counting X-ray imaging systemIEEE Transactions on Nuclear Science, 2001
- Signal-to-noise optimization of medical imaging systemsJournal of the Optical Society of America A, 1999
- A method for measuring the presampled MTF of digital radiographic systems using an edge test deviceMedical Physics, 1998
- A spatial‐frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systemsMedical Physics, 1994