This work focuses on fabricating poly(2-aminobenzylamine)-modified screen-printed carbon electrode as an electrochemical immunosensor for the label-free detection of human immunoglobulin G. To selectively detect immunoglobulin G, the anti-immunoglobulin G antibody with high affinity to immunoglobulin G was covalently linked with the amine group of poly(2-aminobenzylamine) film-deposited screen-printed carbon electrode. The selectivity for immunoglobulin G was subsequently assured by being challenged with redox-active interferences and adventitious adsorption did not significantly interfere the analyte signal. To obviate the use of costly secondary antibody, the [Fe(CN)6]4-/3- redox probe was instead applied to measure the number of human immunoglobulin G through the immunocomplex formation that is quantitatively related to the level of the differential pulse voltammetric current. The resulting immunosensor exhibited good sensitivity with the detection limit of 0.15 ng mL−1, limit of quantitation of 0.50 ng mL−1 and the linear range from 1.0 to 50 ng mL−1. Given those striking analytical performances and the affordability arising from using cheap screen-printed carbon electrode with label-free detection, the immunosensor serves as a promising model for the next-step development of a diagnostic tool.Keywords
This publication has 38 references indexed in Scilit:
- Identification and Mapping of Linear Antibody Epitopes in Human Serum Albumin Using High-Density Peptide ArraysPLOS ONE, 2013
- The fabrication of nanosensor-based surface plasmon resonance for IgG detectionArtificial Cells, Nanomedicine, and Biotechnology, 2012
- Ag(I)-cysteamine complex based electrochemical stripping immunoassay: Ultrasensitive human IgG detectionBiosensors and Bioelectronics, 2011
- Detection of Adrenaline on Poly(3-aminobenzylamine) Ultrathin Film by Electrochemical-Surface Plasmon Resonance SpectroscopyLangmuir, 2010
- Sandwich-type amperometric immunosensor for human immunoglobulin G using antibody-adsorbed Au/SiO2 nanoparticlesMicrochimica Acta, 2010
- Immunoglobulin G Subclass Profile of Antimeasles Response in Vaccinated Children and in Adults with Measles HistoryClinical and Vaccine Immunology, 2005
- Sensitive Detection of Human IgG in ELISA Using a Monoclonal Anti-IgG-Peroxidase ConjugateHybridoma and Hybridomics, 2004
- Immunosensors—principles and applications to clinical chemistryClinica Chimica Acta; International Journal of Clinical Chemistry, 2001
- Determination of anticholinesterase pesticides in real samples using a disposable biosensorAnalytica Chimica Acta, 1997
- Relative Importance of Cellular and Humoral Immunity in Human Renal TransplantationAnnals of Surgery, 1971