Real-Time High-Resolution MRI Endoscopy at up to 10 Frames per Second
Open Access
- 1 January 2021
- journal article
- research article
- Published by American Association for the Advancement of Science (AAAS) in BME Frontiers
Abstract
Objective. Atherosclerosis is a leading cause of mortality and morbidity. Optical endoscopy, ultrasound, and X-ray offer minimally invasive imaging assessments but have limited sensitivity for characterizing disease and therapeutic response. Magnetic resonance imaging (MRI) endoscopy is a newer idea employing tiny catheter-mounted detectors connected to the MRI scanner. It can see through vessel walls and provide soft-tissue sensitivity, but its slow imaging speed limits practical applications. Our goal is high-resolution MRI endoscopy with real-time imaging speeds comparable to existing modalities. Methods. Intravascular (3mm) transmit-receive MRI endoscopes were fabricated for highly undersampled radial-projection MRI in a clinical 3-tesla MRI scanner. Iterative nonlinear reconstruction was accelerated using graphics processor units connected via a single ethernet cable to achieve true real-time endoscopy visualization at the scanner. MRI endoscopy was performed at 6-10 frames/sec and 200-300μm resolution in human arterial specimens and porcine vessels ex vivo and in vivo and compared with fully sampled 0.3 frames/sec and three-dimensional reference scans using mutual information (MI) and structural similarity (3-SSIM) indices. Results. High-speed MRI endoscopy at 6-10 frames/sec was consistent with fully sampled MRI endoscopy and histology, with feasibility demonstrated in vivo in a large animal model. A 20-30-fold speed-up vs. 0.3 frames/sec reference scans came at a cost of 7 in MI and 45 in 3-SSIM, with reduced motion sensitivity. Conclusion. High-resolution MRI endoscopy can now be performed at frame rates comparable to those of X-ray and optical endoscopy and could provide an alternative to existing modalities, with MRIs advantages of soft-tissue sensitivity and lack of ionizing radiation.Funding Information
- Russell H Morgan Professorship in Radiology
- Siemens Medical Systems
- National Institutes of Health (R01 EB007829)
This publication has 40 references indexed in Scilit:
- A Tale of Coronary Artery Disease and Myocardial InfarctionThe New England Journal of Medicine, 2012
- High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3TJournal of Cardiovascular Magnetic Resonance, 2012
- Towards Real-Time Intravascular Endoscopic Magnetic Resonance ImagingJACC: Cardiovascular Imaging, 2010
- Content-weighted video quality assessment using a three-component image modelJournal of Electronic Imaging, 2010
- Turning Up the Heat on MRIJournal of the American College of Radiology, 2008
- Atherothrombosis and High-Risk Plaque: Part I: Evolving ConceptsJournal of Invasive Cardiology, 2005
- Ultrasound Measurement of the Fibrous Cap in Symptomatic and Asymptomatic Atheromatous Carotid PlaquesJournal of the American College of Cardiology, 2005
- Image Quality Assessment: From Error Visibility to Structural SimilarityIEEE Transactions on Image Processing, 2004
- Medical image registration using mutual informationProceedings of the IEEE, 2003
- Symmetric pulses to induce arbitrary flip angles with compensation for rf inhomogeneity and resonance offsetsJournal of Magnetic Resonance (1969), 1991