Abstract
When a sensitive host inhales aerosols containing these bacteria, Legionella infection occurs. Therefore, monitoring and assessing Legionella in the environment and water distribution systems of such places are critical due to the prone population in hospitals. However, the health risks of Legionella bacteria in the environment are not adequately evaluated. In this study, for hospitalized patients, we performed a quantitative health risk assessment of Legionella in selected hospitals in Tehran city using two scenarios of shower and toilet faucet exposure. This study identified Legionella in 38 cases (38%) out of 100 samples collected from toilet faucets and showers in 8 hospitals. The information gathered was used for quantitative microbial risk assessment (QMRA). The microbial load transmitted by inhalation was calculated using the concentration of Legionella in water. Other exposure parameters (inhalation rate and exposure time) were obtained using information from other studies and the median length of hospital stay (3.6 days). The exponential model was used to estimate the risk of infection (γ = 0.06) due to Legionella pneumophila (L. pneumophila) inhalation for each exposure event. For the mean concentration obtained for Legionella (103 CFU/L), the risk of infection for toilet faucets and showers was in the range of 0.23–2.3 and 3.5–21.9, respectively, per 10,000 hospitalized patients. The results were compared with the tolerable risk level of infection determined by the US EPA and WHO. The risk values exceeded the WHO values for waterborne pathogens in hospitals in both exposure scenarios. As a result, our QMRA results based on monitoring data showed that despite using treated water (from distribution networks in the urban areas) by hospitals, 38% of the samples were contaminated with Legionella, and faucets and showers can be sources of Legionella transmission. Hence, to protect the health of hospitalized patients, the risk of Legionella infection should be considered.Keywords
This publication has 34 references indexed in Scilit:
- An in-premise model for Legionella exposure during showering eventsWater Research, 2011
- Pontiac fever among retirement home nurses associated with airborne legionellaJournal of Hospital Infection, 2011
- Parameters predictive of Legionella contamination in hot water systems: Association with trace elements and heterotrophic plate countsWater Research, 2011
- A Quantitative Microbial Risk Assessment Model for Legionnaires' Disease: Animal Model Selection and Dose‐Response ModelingRisk Analysis, 2007
- Quantitative Microbial Risk Assessment Model for Legionnaires' Disease: Assessment of Human Exposures for Selected Spa OutbreaksJournal of Occupational and Environmental Hygiene, 2007
- Correlation Between Legionella Contamination in Water and Surrounding AirInfection Control & Hospital Epidemiology, 2006
- Legionella pneumophilain aerosols from shower bathsEpidemiology and Infection, 1984
- LEGIONELLACEAE IN THE HOSPITAL WATER-SUPPLY: Epidemiological Link with Disease and Evaluation of a Method for Control of Nosocomial Legionnaires' Disease and Pittsburgh PneumoniaThe Lancet, 1983
- Mechanisms of infection in the respiratory tractNew Zealand Veterinary Journal, 1981
- Legionnairesʼ DiseaseMedicine, 1980