Rapid Identification of a Cooling Tower-Associated Legionnaires' Disease Outbreak Supported by Polymerase Chain Reaction Testing of Environmental Samples, New York City, 2014-2015
- 1 April 2018
- journal article
- research article
- Vol. 80 (8), 8-12
Abstract
We investigated an outbreak of eight Legionnaires' disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) <1 km from patient residences, a market misting system, a community-wide water system used for heating and cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings.Keywords
This publication has 15 references indexed in Scilit:
- Legionnaires' diseaseThe Lancet, 2015
- Refining Historical Limits Method to Improve Disease Cluster Detection, New York City, New York, USAEmerging Infectious Diseases, 2015
- A large community outbreak of Legionnaires’ disease in Vila Franca de Xira, Portugal, October to November 2014Eurosurveillance, 2014
- Epidemiological investigation of a Legionnaires' disease outbreak in Christchurch, New Zealand: the value of spatial methods for practical public healthEpidemiology and Infection, 2012
- Specific Real-Time PCR for Simultaneous Detection and Identification of Legionella pneumophila Serogroup 1 in Water and Clinical SamplesApplied and Environmental Microbiology, 2011
- Design and implementation of a protocol for the detection of Legionella in clinical and environmental samplesDiagnostic Microbiology and Infectious Disease, 2008
- Presence and Chromosomal Subtyping of Legionella Species in Potable Water Systems in 20 Hospitals of Catalonia, SpainInfection Control & Hospital Epidemiology, 2001
- Incidence of community-acquired pneumonia requiring hospitalization. Results of a population-based active surveillance Study in Ohio. The Community-Based Pneumonia Incidence Study Group.1997
- Communitywide Outbreak of Legionnaires' Disease Associated with a Grocery Store Mist MachineThe Journal of Infectious Diseases, 1992
- Variation in time and space of non–outbreak Legionnaires' disease in ScotlandEpidemiology and Infection, 1991