Urea Amperometric Biosensors Based on Nanostructured Polypyrrole and Poly Ortho-Phenylenediamine
Open Access
- 1 January 2013
- journal article
- Published by Scientific Research Publishing, Inc. in Open Journal of Applied Biosensor
- Vol. 02 (01), 12-19
- https://doi.org/10.4236/ojab.2013.21002
Abstract
Urea Amperometric biosensor was obtained on the base of nanostructured polypyrrole (PPy) and poly ortho- phenylenediamine (POPDA). The optimal conditions for monomer electropolymerization were determined. The effect of supporting electrolyte and number of deposition cycles on the OPDA and Py electropolymerization were studied. It was proved that POPDA and PPy were affected by pH changes and responded to the ammonium, product of urease catalyzed reaction. SEM images of the modified Pt/PPy electrode were presented. The cycle voltammograms and chrono amperometric curves of Pt/POPDA/urease and Pt/PPy/urease electrodes were studied. A good linear relationship was observed for Pt/POPDA/urease electrode in a concentration range from 6.7 to 54 mMurea. For Pt/PPy/urease electrode the linear relation in the range from 0.02 to0.16 mMurea was determined. The entrapped carbon nanotubes (CNT) in PPy film and the bipolymer layers were prepared for construction of Pt/PPy/CNT/urease, Pt/POPDA/PPy/urease and Pt/PPy/POPDA/urease biosensors. Obviously, the addition of POPDA to the composition of the two biosensors (Pt/PPy/POPDA/urease and Pt/POPDA/PPy/urease) reduced their sensitivity to urea. Pt/РPy/CNT/urease and Pt/РPy/ urease biosensors were 173 and 138 times more sensitive to urea than biosensor without PPy (Pt/POPDA/urease biosensor). It was found, that the performance of Pt/PPy/CNT/urease electrode was the best from the five obtained biosensors: linear range of urea concentrations—from 0.02 to0.16 mM; sensitivity—15.22 μA/mM and detection limit— 0.005 mM urea.Keywords
This publication has 18 references indexed in Scilit:
- Urea Amperometric Biosensors Based on Nanostructured PolypyrroleElectroanalysis, 2011
- Potentiometric urea biosensor based on urease immobilized by an electrosynthesized poly(o-phenylenediamine) film with buffering capabilitySensors and Actuators B: Chemical, 2011
- Urea amperometric biosensors based on a multifunctional bipolymeric layer: Comparing enzyme immobilization methodsSensors and Actuators B: Chemical, 2009
- Amperometric Urea Biosensor Using Aminated Glassy Carbon Electrode Covered with Urease Immobilized Carbon Sheet, Based on the Electrode Oxidation of Carbamic AcidElectroanalysis, 2007
- Carbon-nanotubes doped polypyrrole glucose biosensorAnalytica Chimica Acta, 2005
- Reduction of interference signal of ascorbate and urate in poly(pyrrole)-based ammonia sensors in aqueous solutionsElectrochimica Acta, 2004
- Amperometric pH-sensing biosensors for urea, penicillin, and oxalacetateAnalytica Chimica Acta, 2000
- Electropolymerization of pyrrole and phenylenediamine over an organic conducting salt based amperometric sensor of increased selectivity for glucose determinationAnalytica Chimica Acta, 1999
- Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensorAnalytica Chimica Acta, 1997
- Polypyrrole-based amperometric flow injection biosensor for ureaAnalytica Chimica Acta, 1996