Using a consumer-based wearable activity tracker for physical activity goal setting and measuring steps in pregnant women with gestational diabetes mellitus: exploring acceptance and validity
Open Access
- 8 June 2021
- journal article
- research article
- Published by Springer Science and Business Media LLC in BMC Pregnancy and Childbirth
- Vol. 21 (1), 1-10
- https://doi.org/10.1186/s12884-021-03900-8
Abstract
Background Activity monitoring devices may be used to facilitate goal-setting, self-monitoring, and feedback towards a step-based physical activity (PA) goal. This study examined the performance of the wrist-worn Fitbit Charge 3™ (FC3) and sought opinions on walking and stepping-in-place from women with gestational diabetes (GDM). Methods Participants completed six 2-min metronome-assisted over ground bouts that varied by cadence (67, 84, or 100 steps per minute) and mode (walking or stepping-in-place; N = 15), with the sequence randomized. Steps were estimated by FC3 and measured, in duplicate, by direct observation (hand-tally device, criterion). Equivalence testing by the two one-sided tests (TOST) method assessed agreement within ± 15%. Mean absolute percent error (MAPE) of steps were compared to 10%, the accuracy standard of the Consumer Technology Association (CTA)™. A subset (n = 10) completed a timed, 200-m self-paced walk to assess natural walking pace and cadence. All participants completed semi-structured interviews, which were transcribed and analyzed using descriptive and interpretive coding. Results Mean age was 27.0 years (SD 4.2), prepregnancy BMI 29.4 kg/m2 (8.3), and gestational age 32.8 weeks (SD 2.6). The FC3 was equivalent to hand-tally for bouts of metronome-assisted walking and stepping-in-place at 84 and 100 steps per minute (i.e., P < .05), although walking at 100 steps per minute (P = .01) was no longer equivalent upon adjustment for multiple comparisons (i.e., at P < .007). The FC3 was equivalent to hand-tally during the 200-m walk (i.e., P < .001), in which mean pace was 68.2 m per minute (SD 10.7), or 2.5 miles per hour, and mean cadence 108.5 steps per minute (SD 6.5). For walking at 84 and 100 steps per minute, stepping-in-place at 100 steps per minute, and the 200-m walk, MAPE was within 10%, the accuracy standard of the CTA™. Interviews revealed motivation for PA, that stepping-in-place was an acceptable alternative to walking, and competing responsibilities made it difficult to find time for PA. Conclusions The FC3 appears to be a valid step counter during the third trimester, particularly when walking or stepping-in-place at or close to women’s preferred cadence.This publication has 30 references indexed in Scilit:
- A Pilot Walking Program Promotes Moderate-Intensity Physical Activity during PregnancyMedicine & Science in Sports & Exercise, 2014
- Reducing the Decline in Physical Activity during Pregnancy: A Systematic Review of Behaviour Change InterventionsPLOS ONE, 2013
- The Stanford Leisure-Time Activity Categorical Item (L-Cat): a single categorical item sensitive to physical activity changes in overweight/obese womenInternational Journal of Obesity, 2013
- Energy Cost of Stepping in Place while Watching Television CommercialsMedicine & Science in Sports & Exercise, 2012
- Can sedentary behavior be made more active? A randomized pilot study of TV commercial stepping versus walkingInternational Journal of Behavioral Nutrition and Physical Activity, 2012
- Accuracy of Physical Activity Monitors in Pregnant WomenMedicine & Science in Sports & Exercise, 2011
- How many steps/day are enough? for adultsInternational Journal of Behavioral Nutrition and Physical Activity, 2011
- National trends in self-reported physical activity and sedentary behaviors among pregnant women: NHANES 1999–2006Preventive Medicine, 2010
- Effect of Pedometer-Based Physical Activity InterventionsResearch Quarterly for Exercise and Sport, 2009
- Translating Physical Activity Recommendations into a Pedometer-Based Step Goal: 3000 Steps in 30 MinutesAmerican Journal of Preventive Medicine, 2009