Cervical Characterization with Tactile-Ultrasound Probe
Open Access
- 1 January 2020
- journal article
- research article
- Published by Scientific Research Publishing, Inc. in Open Journal of Obstetrics and Gynecology
- Vol. 10 (01), 85-99
- https://doi.org/10.4236/ojog.2020.101008
Abstract
Background: Premature cervical softening and shortening may be considered an early mechanical failure that predisposes to preterm birth. Preliminary clinical studies demonstrate that cervical elastography may be able to quantify this phenomenon and predict spontaneous preterm delivery. Objective: To explore a new approach for cervix elasticity and length measurements with tactile-ultrasound probe. Methods: Cervix probe has tactile array and ultrasound transducer designed to apply controllable load to cervix and acquire stress-strain data for calculation of cervical elasticity (Young’s modulus) and cervical length for four cervix sectors. Average values, standard deviations, intraclass correlation coefficients and the 95% limits of agreement (Bland-Altman plots) were estimated. Results: Ten non-pregnant and ten pregnant women were examined with the probe. The study with non-pregnant women demonstrated a reliable acquisition of the tactile signals. The ultrasound signals had a prolonged appearance; identification of the internal os of the cervix in these signals was not reliable. The study with pregnant women with the gestational age of 25.4 ± 2.3 weeks demonstrated reliable data acquisition with real-time visualization of the ultrasound signals. Average values for cervical elasticity and standard deviations of 19.7 ± 15.4 kPa and length of 30.7 ± 6.6 mm were calculated based on two measurements per 4 sectors. Measurement repeatability calculated as intraclass correlation coefficients between two measurements at the same cervix sector on pregnant women was found to be 0.97 for cervical elasticity and 0.93 for the cervical length. The 95% limits of agreement of 1) cervical elasticity were from ?22.4% to +14.9%, and 2) cervical length from ?13.3% to +16.5%. Conclusions: This study demonstrated clinically acceptable measurement performance and reproducibility. The availability of stress-strain data allowed the computation of cervical elasticity and length. This approach has the potential to provide cervical markers to predict spontaneous preterm delivery.Keywords
This publication has 50 references indexed in Scilit:
- Risk Factors for Preterm Birth in an International Prospective Cohort of Nulliparous WomenPLOS ONE, 2012
- National, regional, and worldwide estimates of preterm birth rates in the year 2010 with time trends since 1990 for selected countries: a systematic analysis and implicationsThe Lancet, 2012
- First-Trimester Screening for Spontaneous Preterm Delivery with Maternal Characteristics and Cervical LengthFetal Diagnosis and Therapy, 2012
- Long-term neurodevelopmental outcomes after intrauterine and neonatal insults: a systematic reviewThe Lancet, 2012
- Molecular Markers of Preterm Labor in the ChoriodeciduaReproductive Sciences, 2009
- Health Among Caregivers of Children With Health Problems: Findings From a Canadian Population-Based StudyAmerican Journal of Public Health, 2009
- Preterm Prediction StudyObstetrics & Gynecology, 2008
- Soft tissue elastometerMedical Engineering & Physics, 2008
- Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variablesUltrasound in Obstetrics & Gynecology, 2008
- Applying the right statistics: analyses of measurement studiesUltrasound in Obstetrics & Gynecology, 2003