Adverse Events Associated With Deep Brain Stimulation for Movement Disorders

Abstract
Although numerous studies have focused on the efficacy of deep brain stimulation (DBS) for movement disorders, less is known about surgical adverse events, especially over longer time intervals. Here, we analyze adverse events in 510 consecutive cases from a tertiary movement disorders center at up to 10 years postoperatively. We conducted a retrospective review of adverse events from craniotomies between January 2003 and March 2013. The adverse events were categorized into 2 broad categories—immediate perioperative and time-dependent postoperative events. Across all targets, perioperative mental status change occurred in 18 (3.5%) cases, and symptomatic intracranial hemorrhage occurred in 4 (0.78%) cases. The most common hardware-related event was skin erosion in 13 (2.5%) cases. The most frequent stimulation-related event was speech disturbance in 16 (3.1%) cases. There were no significant differences among surgical targets with respect to the incidence of these events. Time-dependent postoperative events leading to the revision of a given DBS electrode for any reason occurred in 4.7% ± 1.0%, 9.3% ± 1.4%, and 12.4% ± 1.5% of electrodes at 1, 4, and 7 years postoperatively, respectively. Staged bilateral DBS was associated with approximately twice the risk of repeat surgery for electrode replacement vs unilateral surgery (P = .020). These data provide low incidences for adverse events in a large series of DBS surgeries for movement disorders at up to 10 years follow-up. Accurate estimates of adverse events will better inform patients and caregivers about the potential risks and benefits of surgery and provide normative data for process improvement.